IP-A1AF ( TOA ) IP Audio Interface
Power Source |
PoE+ (IEEE802.3at Class 4), PoE (IEEE802.3af Class 3) |
---|---|
Power Consumption |
22 W (at PoE+ powered, rated output) 12.95 W (at PoE powered, rated output) 5 W (IEC62368-1) |
Amplifier Rated Output |
15 W (at PoE+ powered, 8 Ω) 8 W (at PoE powered, 8 Ω) Applicable impedance: 8 - 16 Ω |
Frequency Response |
50 Hz - 20 kHz |
Audio Codec |
PCMU (G.711u), PCMA (G.711a), G.722 |
Audio Delay Time |
Min. 100 ms (1*) |
Broadcasting Mode |
SIP Broadcasting/SIP calling Mode: PCMU/PCMA/G.722, P2P/SIP Server Connection Multicast Broadcasting Mode: PCMU/PCMA/G.722 Auto codec recognition, 20 ports VMS Broadcasting Mode: ONVIF Audio Backchannel, PCMU Internal Message Broadcasting Mode Local Broadcasting Mode: Output from LINE/MIC IN to SPEAKER OUT Note: Each broadcast model can be assigned an order of priority using the Priority Setting function. |
Internal Messages |
Max. 20 messages (Max. recording capacity: 80 MB) Supported file formats: WAV file: 8/16/44.1/48 kHz sampling frequency, 8/16 bit, monaural/stereo MP3 file: 32/44.1/48 kHz sampling frequency, 64-320 kbps, CBR/VBR, monaural/stereo Repeat playback: Playcount (1-10 times), Duration (5-3600 sec) or Timer (from Start time to End time) Interval time: 0-60 sec, Delay time: 0-30 sec Trigger: Contol Input or Remote API (HTTP) |
Network I/F |
100BASE-TX, Auto MDI/MDI-X, RJ-45 connector |
Network Protocol |
TCP/IP, UDP, HTTP, RTP, RTSP, RTCP, ARP, ICMP, IGMPv3, NTP, SIP (RFC3261) |
Audio Input |
1 channel, electronically-balanced, 10 kΩ LINE/MIC selectable (Rated input: LINE: 0 dB (2*), MIC: -60 dB (2*) PAD function (-20 dB (2*), Phantom power ON/OFF (12 V DC), volume adjustable removable terminal block (6 pins) |
Audio Output |
1 channel, electronically-balanced, 600 Ω or less Rated output: 0 dB (2*), removable terminal block (6 pins) |
Control Input |
2 channels, no-voltage make contact inputs, open voltage: 5 V DC, short-circuit current: 2 mA or less, removable terminal block (6 pins) |
Control Output |
1 channel, open collector output, withstand voltage 30 V DC, control current: 10 mA or less, removable terminal block (6 pins) |
Indicator |
STATUS (green/blue/yellow/red), LINE/MIC IN (green/red), OUTPUT (green), LINK/ACT (green) |
Clock Accuracy |
±13 seconds per month |
Time Adjustment |
Manual time setting, Time adjustment by NTP server |
Power Outage Protection Period |
24 hours (RTC time retention, at 40 °C) |
Operating Temperature |
-30 °C to +55 °C |
Operating Humidity |
90 %RH or less (no condensation) |
Finish |
Front Case: Surface-treated steel plate, black, paint Rear Chassis: Surface-treated steel plate |
Dimensions |
126 (W) x 33 (H) x 80 (D) mm |
Weight |
390 g |
Accessory |
Removable terminal plug (6 pins, preinstalled on the unit) x 2 Removable terminal plug (2 pins, preinstalled on the unit) x 1 Rubber feet x 4 Mounting screw (M3 x 6) x 4 |